Extra 8% Off sitewide with "PD8"
Free shipping





Accidental damage in year one, plus service after the original warranty.
Added as a separate cart item. Terms, conditions and exclusions apply.
We provide free home delivery for orders over $30.
We ship from our CA warehouse whenever stock is available, with delivery typically taking 3–7 days. If items are dispatched from our international warehouse, delivery may take 7–15 days.
All orders are trackable, and you will receive an email with tracking details once your order has been shipped.
With our clinically tested and proven system, we are confident in what we deliver.
You may request a full refund by returning your undamaged products within 30 days. Once the item is received at the Freyara warehouse and passes inspection, the refund process will begin.
For detailed information regarding refunds, please contact our customer service at suri@freyara.com
Freyara offers a one-year warranty to ensure your shopping experience is worry-free.
If your product experiences any quality issues within one year of purchase, simply provide your order receipt and contact our customer service team at suri@freyara.com .
We will assist you with confirmation and provide safe, convenient repair or replacement services.
We'll always be there for you.
We provide product tutorials and dedicated support just for you!
If you have any questions, please feel free to contact our customer service team at suri@freyara.com
.









How to use?
Eyebrow washing process and precautions
1. Clean the operation area. (Washing eyebrows requires thick application of gel to prevent white eyebrows)
2. Wash from the end of the eyebrows, use a cotton swab to swipe the eyebrows, and the skin will turn white. After the operation, wipe the gel clean, apply erythromycin ointment, wrap a layer of plastic wrap, and ice for 15 minutes
3. If the skin is not broken after the operation, it is recommended to touch water after about 24 hours. If the skin is broken, it cannot touch water before the scab is formed and recovered. Apply erythromycin ointment after the scab to prevent infection. If the skin is not broken but it is more red and swollen, ice it once for the first three days, each time for 15 minutes
4. Normal color eyebrows are applied close to the skin, do not pull the distance, test it close to the skin to see if the skin turns white, if not, raise it 0.5cm, and the maximum should not exceed 1cm
5. Eyebrow washing can only be done once, and it cannot be repeated. Repeated application will cause swelling or bleeding
6. The frequency of the eyebrow washing machine should not be turned too high. If the speed is too fast, white eyebrows will appear. If the eyebrows are white, apply saline for 48 hours and they will recover.
7. It is not recommended to operate eyeliner. Practice eyeliner after you are proficient in eyebrow washing.
8. Check whether the skin has inflammation before washing eyebrows. If you have a scar physique or an allergic physique, you should use it with caution. It is not suitable for patients with diabetes and heart disease.
9. Keep the treatment area clean and avoid friction and infection. During the period of redness and swelling, erythromycin can be used. Apply erythromycin ointment 1 to 2 times a day to prevent infection. It is not advisable to participate in strenuous exercise before the scab falls off (so as not to cause infection after sweating), do not wear makeup, do not rub the skin, do not apply facial masks, do not drink alcohol, and prohibit the use of aspirin. Pay attention to sun protection, otherwise pigmentation may occur, and scars may appear after infection.
Which types of people are not recommended to wash eyebrows?
1. People who have washed eyebrows many times: because the epidermis and dermis become thinner, the relative risk of washing eyebrows is also higher.
2. People who are particularly prone to scarring: People who are prone to scarring on their bodies are prone to scarring or leaving scars, so it is not recommended to wash eyebrows.
3. People with deep eyebrow tattoos: People who have deep eyebrow tattoos are not suitable for eyebrow removal. General eyebrow removal machines usually cannot handle it very effectively and the effect is not good.
4. People with obsessive-compulsive personality tendencies: People with obsessive-compulsive personality tend to be nervous, anxious, eager to do well and have high demands on themselves. Therefore, even if they are very successful, they will still be dissatisfied.
Tattoo removal operation and precautions
1. The recommended distance between tattoo removal and skin is 1-3 cm
2. Tattoo removal is not recommended for those who have had a tattoo for less than one year, and the effect will not be ideal
3. Before tattoo removal, use more than 75% medical alcohol to clean the skin, because there is a stratum corneum and dirt on the skin, so it is not easy to get infected after washing
4. If you can tolerate the pain of tattoo removal, do not apply anesthetics. Anesthetics are easy to proliferate. After tattoo removal, you can apply erythromycin ointment and ice for 15 minutes to prevent blistering and infection
5. When removing tattoos, you can only apply it once at the tattoo site, and you cannot apply it repeatedly
6. The tattoo will scab about 2 days after washing. Remember not to touch water before the scab forms. The scab must fall off naturally and cannot be picked off by hand to prevent scars!
7. After tattoo removal, you can choose to take oral anti-inflammatory drugs for 2-3 days and external repair products to assist skin metabolism
8. Avoid sun exposure and sweating after washing. Avoid spicy foods and dark foods such as soy sauce
9. The interval between tattoo removal is recommended to be more than 30 days, depending on the recovery situation
Precautions after freckle removal
1. The recommended distance for freckle removal is 1-2cm
2. After freckle removal, the skin may be red and swollen due to the energy irradiation, but this is normal. Sometimes there will be a slight heat sensation, but it will subside quickly.
3. After freckle removal, apply anti-inflammatory cream every day. The wound will slowly form a scab and fall off after about a week. At this time, the skin will be pink. During this process, pay attention to keep clean and avoid sun exposure, otherwise it will affect the effect of freckle removal.
4. If the pigment has not completely subsided after freckle removal, you don’t have to worry. You can have the next treatment in about 1 month.
5. Pay attention to continuous sun protection after surgery, eat less greasy and spicy food, keep a happy mood, and do not use whitening and irritating functional products.
6. On the 1st to 4th day after surgery, pay attention to "repair" work (apply growth factors), try not to touch water, use saline or distilled water to wipe, keep the treatment area clean and fresh, and apply some repair ointment.
7. Do not steam sauna or do strenuous exercise within seven days. Do not eat irritating and pigmented foods within seven days, such as coriander, celery, leek, spinach, chocolate, coffee, soy sauce, and prohibit smoking and drinking.
8. If there is scab, do not pick it with your hands, and do moisturizing care after ten days.
9. After a week, the wound will begin to scab and fall off. At this time, sun protection is an absolutely necessary step. Wear SPF30+ sunscreen when going out, and protect against the sun for at least 3-6 months.
Black Face Doll: It mainly has the effects of whitening, removing yellowness, controlling oil, and shrinking pores. A course of treatment is 3 to 5 times, and it can be done once a month.
1. After cleansing, apply a thin layer of gel (the gel should not be applied too thickly, as it will absorb light, and it will feel hot and tingling during operation, and it is difficult to blast and easily clog pores). After applying the gel, wait for the gel to dry before operating.
2. During operation, replace the black black face doll special operation head with energy between 200 and 500, mainly depending on the blasting force (the degree to which the gel can be blasted cleanly), 1-2cm away from the skin, and the frequency is 2~5hz (2hz is recommended for novices)
3. One part can only be applied once, not multiple times. Each part must be operated, and it cannot be applied casually, otherwise the blasting will not be clean and affect the effect
4. After the black face doll, you can wash your face with clean water after five minutes, and then apply a moisturizing mask, and then you can do normal skin care, and hydrate more in the later stage.
Probe function:
Non-invasive 1064nm red probe:
For washing black and blue eyebrows, eyeliner
Energy: 200-300mj, frequency: 1-3hz
Non-invasive 532nm blue probe:
Washing red, brown and coffee eyebrows
Energy: 200-300mj, frequency: 1-3hz
Minimally invasive 1064nm (colorless) probe:
Washing black and blue tattoos, removing deep spots
Tattoo removal energy: 300-600mj
Freckle removal energy: 600-10 00mj
Frequency: 1-3hz
Minimally invasive 532nm (colorless) probe:
Remove colored tattoos, remove shallow spots
Tattoo removal energy: 300-600mj
Spot removal energy: 600-1000mj
Frequency: 1-3hz
Black face doll probe:
Whitening, yellowing, oil control, shrink pores
Energy: 200-500mj, frequency: 2-5hz
Eyeliner Probe:
Remove eyeliner
Energy: 200-400mj, frequency: 1-3hz
CAUTION
1. Keep the pedal pressed and do not release it, not one step at a time, this design is safer!
2. Practice on A4 paper before use. You can use a pen to blacken and operate the instrument on the black text
3. Be careful not to switch on and off at will, it is very dangerous!
4. Women cannot use it during menstruation
5. It is not recommended to operate it by yourself. You need to wear an eye mask when using it to avoid accidental injury to your eyes
Specifications:
Pulse energy: 500-6000MJ
Pulse width: 3-20NS
Frequency speed: 1-10HZ
Voltage:110V-240V
Power: 3000W
Wavelength: 1064nm/755nm/532nm
Weight: 8KG
Size: 50*35*25CM
Packing List:
Picosecond Machine*1
Handle*1
Goggles*1
Eye Protection*1
Operation Head*6
Manual*1
SUITCASE SYSTEM
FacialPure 5.0 integrates the professional laser platform into a compact suitcase-style body for easier transport, storage and workspace organization.
Place the system on a stable, dry and well-ventilated treatment surface before operation.
MAIN CONSOLE
The professional control interface provides access to pulse energy, repetition rate and treatment settings.
LASER HANDPIECE
The system uses one professional treatment handpiece with six interchangeable treatment probes.
6-PROBE SYSTEM
The current probe configuration includes:
• 1320-F0 Carbon Peel Probe
• 532-F50 Probe
• 1064-F50 Probe
• 532 nm Non-Invasive Probe
• 1064 nm Non-Invasive Probe
• Precision Tip
PULSE-ENERGY CONTROL
Adjust pulse energy across the listed:
500–6000 mJ range
PULSE-REPETITION CONTROL
Adjust repetition rate from:
1–10 Hz
FOOT-PEDAL CONTROL
Position the treatment handpiece over the selected treatment area and use the foot pedal to activate treatment output.
COOLING SYSTEM
FacialPure 5.0 is designed without routine user water-refill requirements, simplifying system setup and maintenance compared with refill-based configurations.
POWER SYSTEM
Input Voltage:
AC 110–240 V
Peak Power:
3000 W
Operation:
Corded Professional System
1064 nm NON-INVASIVE PROBE — Dark Permanent-Makeup Pigment
Designed for darker permanent-makeup pigment routines.
Best for:
• Black Eyebrow Pigment
• Blue Eyebrow Pigment
• Dark Permanent Makeup
532 nm NON-INVASIVE PROBE — Red & Brown Permanent Makeup
Designed for warmer permanent-makeup pigment colours.
Best for:
• Red Eyebrow Pigment
• Brown Eyebrow Pigment
• Coffee-Tone Permanent Makeup
1064-F50 PROBE — Dark Tattoos & Deeper Pigmentation
Designed for darker tattoo pigment and deeper pigment-focused professional routines.
Best for:
• Black Tattoos
• Blue Tattoos
• Dark Pigmentation
• Deeper Pigment-Focused Care
532-F50 PROBE — Coloured Tattoos & Surface Pigmentation
Designed for coloured tattoo pigment and shallower pigment-focused routines.
Best for:
• Coloured Tattoos
• Red / Brown Pigment
• Superficial Spots
• Surface Pigmentation
1320-F0 CARBON PEEL PROBE — Facial Surface Care
Designed for compatible Carbon Peel skincare routines.
Best for:
• Oil-Control Focused Care
• Pore-Appearance Care
• Surface Cleansing
• Brightening-Focused Care
PRECISION TIP — Fine-Area Professional Care
Designed for controlled precision treatment placement over suitable small professional treatment areas.
PULSE ENERGY — 500–6000 mJ
Adjust treatment energy according to the selected probe and professional treatment routine.
REPETITION RATE — 1–10 Hz
Lower repetition rates provide slower, more deliberate pulse delivery.
Higher repetition rates provide faster treatment progression.
FOOT PEDAL
Position the treatment handpiece first, then activate output through the foot pedal.
1. Place FacialPure 5.0 on a stable professional treatment surface.
2. Connect the treatment handpiece, foot pedal and power supply.
3. Inspect the system and treatment probe before use.
4. Choose the probe that matches the intended treatment routine.
5. Install the selected probe securely before enabling output.
6. Clean and prepare the selected treatment area.
7. Put on the appropriate protective eyewear.
8. Turn on the system.
9. Select the desired pulse-energy setting.
10. Select the desired repetition rate.
11. Begin with appropriate initial treatment parameters.
12. Position the treatment handpiece accurately over the selected area.
13. Use the foot pedal to activate treatment output.
14. Work systematically across the selected treatment area.
15. Avoid unnecessary repeated output over the same point.
16. Stop treatment output before changing probes.
17. Turn off and disconnect the system after completing the routine.
18. Clean reusable treatment components.
19. Store the treatment probes, handpiece, pedal and protective accessories securely after use.
20. Keep the suitcase system clean, dry and well ventilated during storage.
Brand:
FREYARA
Series:
FacialPure 5.0
SKU:
FY28.0004US
Device Type:
Professional Multi-Wavelength Picosecond Laser System
System Format:
Compact Integrated Suitcase
Treatment Handpieces:
1
Interchangeable Treatment Probes:
6
System Wavelengths:
1064 nm / 755 nm / 532 nm
1064 nm Probe Configurations:
Yes
532 nm Probe Configurations:
Yes
Carbon Peel Probe:
Included
Precision Tip:
Included
Pulse Energy:
500–6000 mJ
Pulse Width:
3–20 ns
Pulse Repetition Rate:
1–10 Hz
Peak Power:
3000 W
Input Voltage:
AC 110–240 V
Output Activation:
Foot Pedal
Operation:
Corded Professional System
User Water Refill:
Not Required
Product Size:
Approx. 50 × 35 × 25 cm
Product Weight:
Approx. 8 kg
Protective Goggles:
Included
Additional Eye Protection:
Included
Warranty:
One-Year Limited FREYARA Warranty
Your FREYARA FacialPure 5.0 is backed by a one-year limited warranty and a 30-day money-back guarantee.
If you experience a product issue, contact FREYARA Customer Support with your order number, product SKU, machine serial number and clear photos or video showing the issue.
Return authorization is required before sending the product back.
Treatment probes, protective accessories and other replaceable components are covered according to the applicable warranty terms.
Damage caused by misuse, unauthorized modification, improper electrical installation, incompatible treatment accessories or improper care is not covered.
Terms, conditions and exclusions apply.
Professional laser safety precautions apply.
FacialPure 5.0 is designed for trained professional operation.
Read the complete operating manual before first use.
Use the treatment probe, wavelength configuration, pulse energy and repetition rate appropriate for the selected professional routine.
Wear suitable protective eyewear throughout laser operation.
Never direct laser output toward an unprotected eye or reflective surface.
Use appropriate eye-protection procedures for suitable permanent-makeup and eye-area routines.
Do not operate over open wounds, burns, active infection or significantly inflamed skin.
Avoid direct treatment over suspicious or visibly changing skin growths.
Avoid excessive repeated treatment output over the same position.
Stop operation if significant burning, blistering, unexpected bleeding, severe swelling or another unusual skin reaction occurs.
Switch off laser output before replacing treatment probes.
Keep the main unit, handpiece, treatment probes, pedal and electrical connections clean and dry.
Maintain adequate ventilation around the suitcase unit during operation.
Q: What is FREYARA FacialPure 5.0?
A: FacialPure 5.0 is a professional compact suitcase-style picosecond laser system with one treatment handpiece, six interchangeable treatment probes, adjustable pulse energy and repetition controls.
Q: What makes FacialPure 5.0 different from FacialPure 4.0?
A: FacialPure 5.0 uses a more compact integrated suitcase format, expands the treatment system to six interchangeable probes, increases the listed pulse-energy range to 500–6000 mJ and uses a 3000 W peak-power architecture while eliminating routine user water-refill requirements.
Q: How many treatment probes are included?
A: Six interchangeable treatment probes are included.
Q: Which probes are included?
A: The system includes a 1320-F0 Carbon Peel Probe, 532-F50 Probe, 1064-F50 Probe, 532 nm Non-Invasive Probe, 1064 nm Non-Invasive Probe and Precision Tip.
Q: What wavelengths does FacialPure 5.0 support?
A: FacialPure 5.0 features a multi-wavelength system built around 1064 nm, 755 nm and 532 nm technology.
Q: What is the 1064 nm Non-Invasive Probe designed for?
A: It is designed for compatible dark permanent-makeup pigment routines including black and blue eyebrow pigment.
Q: What is the 532 nm Non-Invasive Probe designed for?
A: It is designed for compatible red, brown and warm-tone permanent-makeup pigment routines.
Q: What is the 1064-F50 Probe designed for?
A: It is designed for dark tattoo pigment and deeper pigmentation-focused professional routines.
Q: What is the 532-F50 Probe designed for?
A: It is designed for coloured tattoo pigment and more superficial pigmentation-focused routines.
Q: What is the 1320-F0 Carbon Peel Probe designed for?
A: It supports compatible Carbon Peel routines focused on oil control, pore appearance, surface cleansing and brighter-looking skin.
Q: What is the Precision Tip designed for?
A: The Precision Tip is designed for controlled fine-area professional treatment placement.
Q: What is the adjustable pulse-energy range?
A: FacialPure 5.0 provides a listed adjustable pulse-energy range of 500–6000 mJ.
Q: What is the pulse-repetition range?
A: The system provides adjustable repetition control from 1 to 10 Hz.
Q: What is the listed pulse width?
A: FacialPure 5.0 uses a 3–20 ns pulse-width configuration.
Q: What does a lower repetition rate do?
A: Lower repetition settings provide slower and more deliberate pulse delivery for precision treatment placement.
Q: What does a higher repetition rate do?
A: Higher repetition settings provide faster pulse delivery for more efficient treatment progression.
Q: How should pulse energy be selected?
A: Select pulse energy according to the installed treatment probe, pigment characteristics and professional treatment routine.
Q: Does FacialPure 5.0 use a foot pedal?
A: Yes. Foot-pedal activation allows the operator to control treatment output while keeping the handpiece positioned over the selected area.
Q: Why does FacialPure 5.0 use a suitcase design?
A: The compact suitcase architecture makes the complete professional system easier to transport, organize and store while maintaining a full six-probe treatment platform.
Q: Does FacialPure 5.0 require the user to refill cooling water?
A: No. The current FacialPure 5.0 configuration is designed without routine user water-refill requirements.
Q: What is the peak-power specification?
A: FacialPure 5.0 features a listed 3000 W peak-power configuration.
Q: What voltage does FacialPure 5.0 support?
A: It supports AC 110–240 V operation.
Q: How large is FacialPure 5.0?
A: The system measures approximately 50 × 35 × 25 cm.
Q: How much does the system weigh?
A: FacialPure 5.0 weighs approximately 8 kg.
Q: Can FacialPure 5.0 be used for tattoo-focused routines?
A: Yes. Dedicated 1064 nm and 532 nm probe configurations support dark and coloured tattoo-pigment focused professional routines.
Q: Can it be used for permanent eyebrow pigment?
A: Yes. Dedicated non-invasive 1064 nm and 532 nm probe configurations support different permanent eyebrow pigment colours.
Q: Does FacialPure 5.0 support Carbon Peel routines?
A: Yes. A dedicated 1320-F0 Carbon Peel Probe is included.
Q: Are protective goggles included?
A: Yes. Protective goggles and an additional eye-protection accessory are included.
Q: Is FacialPure 5.0 designed for professional use?
A: Yes. FacialPure 5.0 is a professional multi-probe laser platform with adjustable treatment controls and precision handpiece operation.
Q: What comes in the box?
A: The package includes the FacialPure 5.0 main unit, professional treatment handpiece, six interchangeable probes, protective goggles, additional eye protection and user manual.
Q: What warranty is included?
A: FREYARA Canada provides a one-year limited warranty and a 30-day money-back guarantee, subject to the applicable terms and conditions.
I organised the six interchangeable treatment probes before beginning a supervised setup on practice material. The cables and connectors were straightforward once they were organised. A practical advantage is the adjustable repetition rate. Overall, the equipment feels well organised once the setup is understood.
Thank you for sharing your experience, Dylan. We are glad the setup became easier to manage after the first session.
I tested the foot-pedal activation during a supervised setup on a training target. The buttons have a clear response once the operating sequence is understood. I especially liked the organised single-handpiece workflow. Overall, I am pleased with the layout and adjustability.
We appreciate your feedback, Emma. It is helpful to hear that the controls and equipment layout were straightforward to use.
I organised the 1064 nm and 532 nm probe configurations before beginning a supervised setup on a training target. Starting at the lowest permitted setting made the interface easier to learn. I especially liked the six-probe layout. The controls became easy to manage after the first practice session.
We appreciate your feedback, Jack. It is helpful to hear that the controls and equipment layout were straightforward to use.
The adjustable 1–10 Hz repetition control was easy to navigate once the professional operating sequence was familiar. The cables and connectors were straightforward once they were organised. For me, the compact professional format made the equipment easier to organise. The learning curve is manageable and the interface is clear.
Thanks for sharing both the positives and the small usability issues, Nina.
I checked the single treatment handpiece and hose before a supervised setup on practice material. The full manual should be read before the first setup. A practical advantage is the organised single-handpiece workflow. I would make checking the probe before operation a little more straightforward. It works smoothly once the cables and controls become familiar.
We appreciate the detailed feedback, Harper. Your comments are helpful as we improve the first-use guidance.
Thanks for subscribing!