Extra 8% Off sitewide with "PD8"
Free shipping




Accidental damage in year one, plus service after the original warranty.
Added as a separate cart item. Terms, conditions and exclusions apply.
We provide free home delivery for orders over $30.
We ship from our CA warehouse whenever stock is available, with delivery typically taking 3–7 days. If items are dispatched from our international warehouse, delivery may take 7–15 days.
All orders are trackable, and you will receive an email with tracking details once your order has been shipped.
With our clinically tested and proven system, we are confident in what we deliver.
You may request a full refund by returning your undamaged products within 30 days. Once the item is received at the Freyara warehouse and passes inspection, the refund process will begin.
For detailed information regarding refunds, please contact our customer service at suri@freyara.com
Freyara offers a one-year warranty to ensure your shopping experience is worry-free.
If your product experiences any quality issues within one year of purchase, simply provide your order receipt and contact our customer service team at suri@freyara.com .
We will assist you with confirmation and provide safe, convenient repair or replacement services.
We'll always be there for you.
We provide product tutorials and dedicated support just for you!
If you have any questions, please feel free to contact our customer service team at suri@freyara.com
.









How to use?
The instrument needs to be filled with water before turning it on:
1. Open the overflow hole
2. Put the funnel into the water filling hole and add distilled water or purified water (to avoid clogging the water outlet hole)
3. If water seeps out of the overflow hole, it means that the instrument is full of water. Stop adding water and screw the nut back to the overflow hole
4. Turn on the instrument for use
Tip: If you use the instrument every day, add water once every half a month. If you do not use it every day, add water once a month. Replace all the water in the instrument every two months
Eyebrow washing process and precautions
1. Clean the operation area. (Washing eyebrows requires thick application of gel to prevent white eyebrows)
2. Wash from the end of the eyebrows, use a cotton swab to swipe the eyebrows, and the skin will turn white. After the operation, wipe the gel clean, apply erythromycin ointment, wrap a layer of plastic wrap, and ice for 15 minutes
3. If the skin is not broken after the operation, it is recommended to touch water after about 24 hours. If the skin is broken, it cannot touch water before the scab is formed and recovered. Apply erythromycin ointment after the scab to prevent infection. If the skin is not broken but it is more red and swollen, ice it once for the first three days, each time for 15 minutes
4. Normal color eyebrows are applied close to the skin, do not pull the distance, test it close to the skin to see if the skin turns white, if not, raise it 0.5cm, and the maximum should not exceed 1cm
5. Eyebrow washing can only be done once, and it cannot be repeated. Repeated application will cause swelling or bleeding
6. The frequency of the eyebrow washing machine should not be turned too high. If the speed is too fast, white eyebrows will appear. If the eyebrows are white, apply saline for 48 hours and they will recover
7. It is not recommended to operate eyeliner. Practice eyeliner after you are proficient in eyebrow washing
8. Check whether the skin has inflammation before washing eyebrows. If you have a scar physique or an allergic physique, you should use it with caution. It is not suitable for patients with diabetes and heart disease
9. Keep the treatment area clean and avoid friction and infection. During the period of redness and swelling, erythromycin can be used. Apply erythromycin ointment 1 to 2 times a day to prevent infection. It is not advisable to participate in strenuous exercise before the scab falls off (so as not to cause infection after sweating), do not wear makeup, do not rub the skin, do not apply facial masks, do not drink alcohol, and prohibit the use of aspirin. Pay attention to sun protection, otherwise pigmentation may occur, and scars may appear after infection
Which types of people are not recommended to wash eyebrows?
1. People who have washed eyebrows many times: because the epidermis and dermis become thinner, the relative risk of washing eyebrows is also higher
2. People who are particularly prone to scarring: People who are prone to scarring on their bodies are prone to scarring or leaving scars, so it is not recommended to wash eyebrows
3. People with deep eyebrow tattoos: People who have deep eyebrow tattoos are not suitable for eyebrow removal. General eyebrow removal machines usually cannot handle it very effectively and the effect is not good
4. People with obsessive-compulsive personality tendencies: People with obsessive-compulsive personality tend to be nervous, anxious, eager to do well and have high demands on themselves. Therefore, even if they are very successful, they will still be dissatisfied
Tattoo removal operation and precautions
1. The recommended distance between tattoo removal and skin is 1-3 cm
2. Tattoo removal is not recommended for those who have had a tattoo for less than one year, and the effect will not be ideal
3. Before tattoo removal, use more than 75% medical alcohol to clean the skin, because there is a stratum corneum and dirt on the skin, so it is not easy to get infected after washing
4. If you can tolerate the pain of tattoo removal, do not apply anesthetics. Anesthetics are easy to proliferate. After tattoo removal, you can apply erythromycin ointment and ice for 15 minutes to prevent blistering and infection
5. When removing tattoos, you can only apply it once at the tattoo site, and you cannot apply it repeatedly
6. The tattoo will scab about 2 days after washing. Remember not to touch water before the scab forms. The scab must fall off naturally and cannot be picked off by hand to prevent scars!
7. After tattoo removal, you can choose to take oral anti-inflammatory drugs for 2-3 days and external repair products to assist skin metabolism
8. Avoid sun exposure and sweating after washing. Avoid spicy foods and dark foods such as soy sauce
9. The interval between tattoo removal is recommended to be more than 30 days, depending on the recovery situation
Precautions after freckle removal
1. The recommended distance for freckle removal is 1-2cm
2. After freckle removal, the skin may be red and swollen due to the energy irradiation, but this is normal. Sometimes there will be a slight heat sensation, but it will subside quickly.
3. After freckle removal, apply anti-inflammatory cream every day. The wound will slowly form a scab and fall off after about a week. At this time, the skin will be pink. During this process, pay attention to keep clean and avoid sun exposure, otherwise it will affect the effect of freckle removal.
4. If the pigment has not completely subsided after freckle removal, you don’t have to worry. You can have the next treatment in about 1 month.
5. Pay attention to continuous sun protection after surgery, eat less greasy and spicy food, keep a happy mood, and do not use whitening and irritating functional products.
6. On the 1st to 4th day after surgery, pay attention to "repair" work (apply growth factors), try not to touch water, use saline or distilled water to wipe, keep the treatment area clean and fresh, and apply some repair ointment.
7. Do not steam sauna or do strenuous exercise within seven days. Do not eat irritating and pigmented foods within seven days, such as coriander, celery, leek, spinach, chocolate, coffee, soy sauce, and prohibit smoking and drinking.
8. If there is scab, do not pick it with your hands, and do moisturizing care after ten days.
9. After a week, the wound will begin to scab and fall off. At this time, sun protection is an absolutely necessary step. Wear SPF30+ sunscreen when going out, and protect against the sun for at least 3-6 months.
Black Face Doll: It mainly has the effects of whitening, removing yellowness, controlling oil, and shrinking pores. A course of treatment is 3 to 5 times, and it can be done once a month.
1. After cleansing, apply a thin layer of gel (the gel should not be applied too thickly, as it will absorb light, and it will feel hot and tingling during operation, and it is difficult to blast and easily clog pores). After applying the gel, wait for the gel to dry before operating.
2. During operation, replace the black black face doll special operation head with energy between 200 and 500, mainly depending on the blasting force (the degree to which the gel can be blasted cleanly), 1-2cm away from the skin, and the frequency is 2~5hz (2hz is recommended for novices)
3. One part can only be applied once, not multiple times. Each part must be operated, and it cannot be applied casually, otherwise the blasting will not be clean and affect the effect
4. After the black face doll, you can wash your face with clean water after five minutes, and then apply a moisturizing mask, and then you can do normal skin care, and hydrate more in the later stage.
Probe function:
Non-invasive 1064nm red probe:
For washing black and blue eyebrows, eyeliner
Energy: 200-300mj, frequency: 1-3hz
Non-invasive 532nm blue probe:
Washing red, brown and coffee eyebrows
Energy: 200-300mj, frequency: 1-3hz
Minimally invasive 1064nm (colorless) probe:
Washing black and blue tattoos, removing deep spots
Tattoo removal energy: 300-600mj
Freckle removal energy: 600-10 00mj
Frequency: 1-3hz
Minimally invasive 532nm (colorless) probe:
Remove colored tattoos, remove shallow spots
Tattoo removal energy: 300-600mj
Spot removal energy: 600-1000mj
Frequency: 1-3hz
Black face doll probe:
Whitening, yellowing, oil control, shrink pores
Energy: 200-500mj, frequency: 2-5hz
Eyeliner Probe:
Remove eyeliner
Energy: 200-400mj, frequency: 1-3hz
CAUTION
1. Keep the pedal pressed and do not release it, not one step at a time, this design is safer!
2. Practice on A4 paper before use. You can use a pen to blacken and operate the instrument on the black text
3. Be careful not to switch on and off at will, it is very dangerous!
4. Women cannot use it during menstruation
5. It is not recommended to operate it by yourself. You need to wear an eye mask when using it to avoid accidental injury to your eyes
6.Before using for the first time, the water tank must be filled with water
Specifications:
Pulse energy: 500-2900MJ
Pulse width: 3-20NS
Frequency speed: 1-10HZ
Voltage:110V-240V
Power: 5000W
Wavelength: 1064nm/785nm/532nm
Weight: 10KG
Size: 46*34*36CM
Packing List:
Picosecond Machine*1
Handle*1
Funnel*1
Pedal*1
Goggles*1
Eye Protection*1
Operation Head*6
Manual*1
SYSTEM SETUP
Place FacialPure 5.0 Ultra on a stable, dry and well-ventilated professional treatment surface.
Lock the trolley system securely in position before operation.
WATER-COOLING SETUP
Before first use, fill the internal water-cooling system.
1. Open the overflow port.
2. Insert the supplied funnel into the water-fill port.
3. Add distilled or purified water.
4. Stop filling when water reaches the overflow port.
5. Close the ports securely before powering on the system.
DUAL-HANDLE SYSTEM
FacialPure 5.0 Ultra uses two dedicated handpieces:
• Picosecond Laser Handpiece
• Ice-Hammer Cooling Handpiece
PICOSECOND LASER HANDPIECE
Use the laser handpiece with the appropriate interchangeable treatment head for pigment, tattoo, permanent-makeup or Carbon Peel routines.
ICE-HAMMER HANDPIECE
Use the dedicated cooling handpiece for localized cooling after compatible laser routines.
LASER TREATMENT HEADS
The laser platform supports six specialized treatment configurations:
• 1064 nm Non-Invasive Head
• 532 nm Non-Invasive Head
• 1064 nm Precision Head
• 532 nm Precision Head
• Carbon Peel / Black Face Doll Head
• Eyeliner Precision Head
PULSE-ENERGY CONTROL
Listed System Range:
500–2900 mJ
PULSE-REPETITION CONTROL
Adjust repetition rate from:
1–10 Hz
FOOT-PEDAL CONTROL
Position the laser handpiece first, then use the foot pedal to control treatment output.
POWER SYSTEM
Input Voltage:
AC 110–240 V
Peak Power:
5000 W
Operation:
Corded Professional System
1064 nm NON-INVASIVE HEAD — Dark Permanent Makeup
Designed for dark permanent-makeup pigment routines.
Best for:
• Black Eyebrow Pigment
• Blue Eyebrow Pigment
• Dark Permanent Makeup
532 nm NON-INVASIVE HEAD — Red & Brown Permanent Makeup
Designed for warm-tone permanent-makeup pigment routines.
Best for:
• Red Eyebrow Pigment
• Brown Eyebrow Pigment
• Coffee-Tone Permanent Makeup
1064 nm PRECISION HEAD — Dark Tattoos & Deeper Pigmentation
Designed for darker tattoo pigment and deeper pigment-focused routines.
Best for:
• Black Tattoos
• Blue Tattoos
• Deep Pigmentation
• Dark Spot Care
532 nm PRECISION HEAD — Coloured Tattoos & Surface Pigmentation
Designed for coloured tattoo pigment and more superficial pigment-focused routines.
Best for:
• Coloured Tattoos
• Red / Brown Pigment
• Superficial Pigmentation
• Surface Spots
CARBON PEEL / BLACK FACE DOLL HEAD — Facial Surface Care
Designed for compatible Carbon Peel routines.
Best for:
• Oil-Control Focused Care
• Pore-Appearance Care
• Surface Cleansing
• Brightening-Focused Care
EYELINER PRECISION HEAD — Fine Pigment Areas
Designed for precision professional treatment of compatible eyeliner and other fine pigment areas.
ICE-HAMMER HANDPIECE — POST-LASER COOLING
Designed for localized cooling after compatible laser routines.
Best for:
• Immediate Post-Laser Cooling
• Skin-Comfort Support
• Localized Cooling Care
• Faster Transition Between Treatment & Cooling
PULSE ENERGY — 500–2900 mJ
Adjust treatment energy according to the installed head and professional treatment protocol.
REPETITION RATE — 1–10 Hz
Lower repetition rates provide slower, more deliberate pulse delivery.
Higher repetition rates provide faster treatment progression.
1. Place FacialPure 5.0 Ultra securely on a stable professional treatment surface.
2. Prepare the internal water-cooling system before first use.
3. Connect the laser handpiece, Ice-Hammer handpiece, foot pedal and power supply.
4. Select the laser treatment head that matches the intended professional routine.
5. Install the treatment head securely before enabling laser output.
6. Clean and prepare the selected treatment area.
7. Put on the appropriate protective eyewear.
8. Turn on the system.
9. Select the desired pulse-energy setting.
10. Select the desired repetition rate.
11. Begin with appropriate initial treatment parameters.
12. Position the laser handpiece accurately over the selected area.
13. Use the foot pedal to activate laser output.
14. Work systematically across the selected treatment area.
15. Stop laser output before changing treatment heads.
16. After the compatible laser routine, switch to the Ice-Hammer handpiece for localized cooling.
17. Complete the cooling routine according to the operating protocol.
18. Turn off and disconnect the system after use.
19. Clean reusable treatment components and handpieces.
20. Check the internal cooling-water system according to the maintenance schedule.
21. Secure the pull rod and trolley system before transport or storage.
Brand:
FREYARA
Series:
FacialPure 5.0 Ultra
SKU:
FY28.0005US
Device Type:
Professional Dual-Handle Multi-Wavelength Laser System
System Format:
Integrated Pull-Rod Trolley Case
Treatment Handpieces:
2
Laser Handpiece:
Picosecond Laser Handpiece
Cooling Handpiece:
Ice-Hammer Handpiece
Interchangeable Laser Treatment Heads:
6
System Wavelengths:
1064 nm / 785 nm / 532 nm
Pulse Energy:
500–2900 mJ
Pulse Width:
3–20 ns
Pulse Repetition Rate:
1–10 Hz
Peak Power:
5000 W
Output Stabilization:
Pre-Ignition Stabilizer
Output Activation:
Foot Pedal
Cooling System:
Integrated Water-Cooling System
Initial Water Fill:
Required
Recommended Water:
Distilled or Purified Water
Input Voltage:
AC 110–240 V
Operation:
Corded Professional System
Product Size:
Approx. 46 × 34 × 36 cm
Product Weight:
Approx. 10 kg
Transport System:
Pull Rod + Built-In Wheels
Protective Goggles:
Included
Additional Eye Protection:
Included
Warranty:
One-Year Limited FREYARA Warranty
Your FREYARA FacialPure 5.0 Ultra is backed by a one-year limited warranty and a 30-day money-back guarantee.
If you experience a product issue, contact FREYARA Customer Support with your order number, product SKU, machine serial number and clear photos or video showing the issue.
Return authorization is required before sending the product back.
Laser treatment heads, Ice-Hammer accessories, protective accessories and other replaceable components are covered according to the applicable warranty terms.
Damage caused by misuse, unauthorized modification, improper electrical installation, incorrect cooling-system maintenance, incompatible accessories or improper care is not covered.
Terms, conditions and exclusions apply.
Professional laser safety precautions apply.
FacialPure 5.0 Ultra is designed for trained professional operation.
Read the complete operating manual before first use.
Prepare and maintain the internal water-cooling system according to the supplied instructions.
Use the treatment head, pulse energy and repetition rate appropriate for the selected professional routine.
Wear suitable protective eyewear throughout laser operation.
Never direct laser output toward an unprotected eye or reflective surface.
Use appropriate protective procedures for permanent-makeup and suitable eye-area treatment routines.
Do not operate over open wounds, burns, active infection or significantly inflamed skin.
Avoid excessive repeated laser output over the same treatment position.
Stop treatment if significant burning, blistering, unexpected bleeding, severe swelling or another unusual skin reaction occurs.
Switch off laser output before replacing treatment heads.
Use the Ice-Hammer handpiece only for compatible cooling routines according to the operating instructions.
Keep the main unit, laser handpiece, cooling handpiece, treatment heads, foot pedal, cooling ports and electrical connections clean and dry.
Maintain adequate ventilation around the trolley unit during operation.
Q: What is FREYARA FacialPure 5.0 Ultra?
A: FacialPure 5.0 Ultra is a professional dual-handle laser system combining a dedicated picosecond laser handpiece, Ice-Hammer cooling handpiece, six interchangeable laser treatment heads, adjustable pulse-energy and repetition controls.
Q: What makes FacialPure 5.0 Ultra different from FacialPure 5.0?
A: FacialPure 5.0 Ultra adds a dedicated Ice-Hammer cooling handpiece, dual-handle workflow, 5000 W peak-power architecture, Pre-Ignition Stabilizer and an integrated pull-rod trolley format for a more complete professional laser-and-cooling workflow.
Q: How many handpieces does FacialPure 5.0 Ultra use?
A: The FacialPure 5.0 Ultra platform is designed around two dedicated handpieces: a picosecond laser handpiece and an Ice-Hammer cooling handpiece.
Q: What does the Ice-Hammer handpiece do?
A: The Ice-Hammer handpiece provides localized cooling after compatible laser routines, allowing the operator to transition directly from laser treatment to cooling care on the same system.
Q: How many laser treatment heads are included?
A: Six interchangeable laser treatment heads are included.
Q: Which laser heads are included?
A: The platform includes 1064 nm and 532 nm Non-Invasive heads, 1064 nm and 532 nm Precision heads, a Carbon Peel / Black Face Doll head and an Eyeliner Precision head.
Q: What wavelengths does FacialPure 5.0 Ultra support?
A: The current FacialPure 5.0 Ultra system lists 1064 nm, 785 nm and 532 nm wavelength technology.
Q: What is the 1064 nm Non-Invasive Head designed for?
A: It is designed for compatible dark permanent-makeup pigment routines including black and blue eyebrow pigment.
Q: What is the 532 nm Non-Invasive Head designed for?
A: It is designed for red, brown and warm-tone permanent-makeup pigment routines.
Q: What is the 1064 nm Precision Head designed for?
A: It is designed for darker tattoo pigment and deeper pigmentation-focused professional routines.
Q: What is the 532 nm Precision Head designed for?
A: It is designed for coloured tattoo pigment and more superficial pigmentation-focused routines.
Q: What is the Carbon Peel / Black Face Doll Head designed for?
A: It supports compatible Carbon Peel routines focused on oil control, pore appearance, surface cleansing and brighter-looking skin.
Q: What is the Eyeliner Precision Head designed for?
A: It is designed for precision professional pigment routines in compatible fine treatment areas including eyeliner pigment.
Q: What is the pulse-energy range?
A: FacialPure 5.0 Ultra lists an adjustable system pulse-energy range of 500–2900 mJ.
Q: What is the pulse-repetition range?
A: The system provides adjustable repetition control from 1 to 10 Hz.
Q: What is the listed pulse width?
A: FacialPure 5.0 Ultra lists a 3–20 ns pulse-width configuration.
Q: What does the Pre-Ignition Stabilizer do?
A: The Pre-Ignition Stabilizer supports stable high-power laser output and consistent professional operating performance.
Q: What is the peak-power specification?
A: FacialPure 5.0 Ultra features a listed 5000 W peak-power configuration.
Q: Does FacialPure 5.0 Ultra use a foot pedal?
A: Yes. The foot pedal allows laser output to be controlled while the operator keeps the treatment handpiece positioned over the selected area.
Q: Does the system require water before first use?
A: Yes. The internal cooling system must be filled with distilled or purified water before first operation.
Q: How often should the cooling system be maintained?
A: The current operating instructions recommend checking and replenishing the cooling system according to use frequency and replacing the system water periodically.
Q: Why does FacialPure 5.0 Ultra use a pull-rod trolley design?
A: The integrated pull rod and wheels make the complete professional system easier to move between treatment rooms, clinics or workspaces.
Q: How much does FacialPure 5.0 Ultra weigh?
A: The system weighs approximately 10 kg.
Q: How large is the system?
A: FacialPure 5.0 Ultra measures approximately 46 × 34 × 36 cm.
Q: What voltage does it support?
A: FacialPure 5.0 Ultra supports AC 110–240 V operation.
Q: Are protective goggles included?
A: Yes. Protective goggles and an additional eye-protection accessory are included.
Q: Is FacialPure 5.0 Ultra designed for professional use?
A: Yes. It is a professional dual-handle laser and cooling platform with adjustable treatment parameters, multiple treatment heads and foot-pedal activation.
Q: What comes in the box?
A: The complete FacialPure 5.0 Ultra package includes the main system, picosecond laser handpiece, Ice-Hammer cooling handpiece, six laser treatment heads, foot pedal, water-filling funnel, protective eyewear and user manual.
Q: What warranty is included?
A: FREYARA Canada provides a one-year limited warranty and a 30-day money-back guarantee, subject to the applicable terms and conditions.
I reviewed the adjustable pulse-energy control during a supervised setup on a training target. The unit feels sturdy on a stable counter or dedicated cart. The workflow feels clearer because of the pull-rod and pulley design. Overall, I am pleased with the layout and adjustability.
We appreciate your feedback, Liam. It is helpful to hear that the controls and equipment layout were straightforward to use.
I reviewed the adjustable pulse-energy control during a supervised setup on a test patch. Cleaning the external contact surfaces after shutdown was straightforward. The workflow feels clearer because of the portable case format. Overall, the equipment feels well organised once the setup is understood.
Thanks for the detailed feedback, Nora. We are pleased that the layout and settings worked well.
I reviewed the adjustable 1–10 Hz frequency control during a supervised setup on an approved practice area. The accessories need a little planning for storage and labelling. A practical advantage is the foot-pedal workflow. The equipment is practical overall, with a few usability details to improve.
We appreciate the detailed feedback, Emma. Your comments are helpful as we improve the first-use guidance.
I reviewed the adjustable 1–10 Hz frequency control during a supervised setup on a test patch. The accessories need a little planning for storage and labelling. A clearer quick-start guide for organising six operation heads would improve the first-use experience. It is a capable setup, although the learning curve is noticeable.
We appreciate the details, Evelyn. Clearer setup guidance is useful feedback for the support materials.
The foot-pedal activation was easy to position once the cable was kept clear of the operator area. Starting at the lowest permitted setting made the interface easier to learn. For me, the portable case format made the equipment easier to organise. The setup would be easier with better guidance for checking the selected head before setup. The learning curve is manageable and the interface is clear.
Thank you for the balanced feedback, Sarah. We have noted your comments about the setup.
Thanks for subscribing!
This email has been registered!